FLP
EExd I / IIC captive cone gland
MAC
- Multi Armour Cone
|
|
Features and
Benefits
• Two part handling,
freely rotating captive cone for earth continuity
and armour clamping.
• Factory fitted with a specially formulated elastomeric seal
provides
built-in safety.
• No loose parts that can get lost.
• Manufactured from high quality brass, nickel plated and stainless steel.
• Complete with an orange thread cap / safety gauge for correct
gland selection.
|
|
|
|
|
|
| Technical
Data |
|
Type |
FLP |
|
Gland Material |
Brass (Nickel Plated), Stainless Steel |
|
Seal Material |
Thermoplastic Elastomer |
|
Cable Type |
Steel Wire, Braid, Tape Armour |
|
Armour Clamping |
Captive Cone and Cone Ring |
|
Sealing Area |
Inner sheath |
|
Optional Accessories |
Shroud, Adaptor/Reducer |
|
|
|
| Standards
and Certifications |
|
Hazardous Area
Classification |
|
|
SANS/SABS IEC |
Zone 1, 2, 21and 22
Exd I / IIC, Exe I / IIC and DIP |
|
CENELEC / ATEX |
Category 2, Category
3, EExde I / II 2 GD, EExd I M2 |
|
Compliance Code |
Certification No. |
|
CENELEC
/ ATEX |
|
|
EN50014:1997E |
DEMKO 01 ATEX 130325X EPSILON 06 ATEX 2044 |
|
EN50018:2000E |
DEMKO 01 ATEX 130325X EPSILON 06 ATEX 2044 |
|
EN50019:2000E |
DEMKO 01 ATEX 130325X EPSILON 06 ATEX 2044 |
|
EN50281-1-1:1999E |
DEMKO 01 ATEX 130325X EPSILON 06 ATEX 2044 |
|
SANS
/ SABS / IEC |
|
|
|
SANS 808 |
SABS MS/W 455U |
|
SANS/SABS IEC 60079-0 |
2000 |
SABS MS/W 455U |
|
SANS/SABS IEC 60079-1 |
2001 |
SABS MS/W 455U |
|
SANS/SABS IEC 60079-7 |
2001 |
SABS MS/W 455U |
|
SANS/SABS IEC 60529 |
1989 |
SABS MS/W 455U |
|
SANS/SABS IEC
61241.1.1 |
1999 |
SABS MS/W 455U |
|
CHINESE |
|
GB3638. 1-2000 part 1 |
|
CNEx09 0428U |
|
GB3638. 2-2000 part 2 |
|
CNEx09 0428U |
|
GB3638. 3-2000 part 3 |
|
CNEx09 0428U |
|
GB12476. 1-2000 |
|
CNEx09 0428U |
|
| Ingress
Protection |
IP66/67/68 |
| Operating
Temperature |
-30°C
to + 130°C |
|
Special Conditions for
Safe Use - X
Glands that incorporate a seal with an uncompressed height of less than 20mm shall not be used with EEX d IIC apparatus that has a volume in excess of 2000cc. If mounted in flame proof enclosures, make sure that at least threads are engaged and that the depth of engagement of enclosures smaller than 100
cm3 are at least 5mm and for enclosures larger than 100